LANtastic Technote
Number: TN5041
|
|
Created
On: 11/21/2001
Product:
LANTASTIC
8.0
Keywords:
LANTASTIC
DOS LOW LEVEL DRIVER
Subject:
ATTEMPTING
TO LOAD AILANBIO ERRORS WITH: "ADAPTER
NUMBER ALREADY IN USE"
Solution:
BACKGROUND:
This error occure when AILANBIO attempts to
load with an adapter number already in use
by another low-level LANtastic driver. This
is a common mistake when the user is trying
to load two or more adapters. Users often
forget to specify a different adapter number
on the AILANBIO command line.
SOLUTION:
For each adapter's low-level driver that loads,
AILANBIO must be loaded with a different adapter
number.
The following example uses a LANtastic NodeRunner
running NR.EXE and a LANtastic NodeRunner
Pro running NPRO.EXE:
NR
AILANBIO
NPRO MPX=C8
AILANBIO MPX=C8 ADAPTER=1
REDIR MACHINE_NAME
SERVER (if running as a server)
DISCLAIMER:
THIS INFORMATION IS PROVIDED "AS IS"
WITHOUT WARRANTY OF ANY KIND, EITHER EXPLICIT
OR IMPLIED. WE HEREBY DISCLAIM ALL WARRANTIES
AND SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL,
CONSEQUENTIAL, INDIRECT, OR PUNITIVE DAMAGES,
OR LOST PROFITS OR REVENUE, EVEN IF IT HAS
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF LIABILITY FOR CONSEQUENTIAL
OR INCIDENTAL DAMAGES, SO THE FOREGOING LIMITATION
MAY NOT APPLY TO YOU.
Brand names, company
names, and product names are trademarks of
their respective companies.
|
|
|
|
|
|