LANtastic Technote
Number: TN4002
|
|
Created
On: 08/11/99
Product:
LANTASTIC
8.0
Keywords:
SN WIN95
98
Subject:
"SERIAL
NUMBER NOT AVAILABLE" ON A WINDOWS 95
COMPUTER RUNNING LANTASTIC 8.0
Solution:
CAUSE:
Artisoft NetBIOS listed twice in the component
list in Network Properties even though only
one network adapter was installed. For example:
Client for LANtastic
NE2000 Compatible
Artisoft LANtastic NetBIOS
Artisoft LANtastic NetBIOS
File and printer sharing for LANtastic Networks
SOLUTION: Remove the excess Artisoft LANtastic
NetBIOS, so the network component list looks
like this:
Client for LANtastic
NE2000 Compatible
Artisoft LANtastic NetBIOS
File and printer sharing for LANtastic Networks